86160 Transmission Meter
Designed specifically for window tint and film (<0.8mm)
Measures IR/UV rejection rate and Visible Light Transmittance (VLT)
Capable of measuring IR rejection, UV rejection, and VLT
Compact, lightweight, and portable
The 86160 Transmission Meter is ideal for testing the transmittance, as well as the ultraviolet (UV) and infrared (IR) rejection rates of automotive films. Its most notable features are its compact design and cost-effectiveness, making it a top choice for solar film exhibitions, manufacturing, quality control, and inspections. This pocket-sized device is widely used across solar film manufacturers, distributors, and automotive tint retailers.
Parameters
Parameter | 86160 Transmission Meter |
---|---|
Size | 93mm *52mm *25m (L*W*H) |
Weight | 70g (exclude batteries) |
Maximum Sample Thickness | <0.8mm |
Resolution | 0.1% |
Accuracy | ±2%(Colorless and transparent material) |
Visible Light Peak Wavelength | 530nm |
UV Peak Wavelength | 365nm |
IR Peak Wavelength | 940nm |
Display | 128*128 Dot matrix LCD |
Battery | 4*AAA alkaline battery |

Features
Compact and Portable
Extremely small and lightweight, making it easy to carry and use anywhere
Instant Operation and Display
Simply place the film in the test slot—results for light transmittance, UV rejection, and IR rejection are displayed immediately
Real-Time Dynamic Calibration
Equipped with a self-calibration function that activates automatically when the test slot is empty, ensuring precise and accurate results
Data Hold Function
Press the HOLD button to lock the displayed data, allowing you to remove the material while keeping the measurements visible on the screen


Energy Efficient
Powered by 4 AAA alkaline batteries, the device consumes very low power and allows easy battery replacement. It also features an auto-shutdown function after 3 minutes of inactivity to conserve energy
Packing
No. | Description | Quantity | Unit |
---|---|---|---|
1 | 86160 Transmission Meter | 1 | pcs |
2 | User Manual | 1 | pcs |
3 | Certificate / Warranty Card | 1 | pcs |
4 | Screwdriver | 1 | pcs |
5 | Spare Screw | 1 | pcs |
6 | Packing Box Dimension 15*8*5 cm(L*W*H) | 1 | pc |
FAQ
-
1.The difference between 86160 (940nm) and 86160A (1400nm) window film transmission meters
The main difference between 86160 and 86160A is that the peak wavelength of the built-in infrared light source is different, 86160: 940nm, 86160A: 1400nm, these two wavelengths are more representative, most of the absorption film has a better blocking effect on 940nm infrared. The metallic film (insulation by reflecting heat) has a better blocking effect on 1400nm infrared. Please choose the appropriate model according to your own film category.
-
2. The difference between 86160 and 86162 window film transmission meters
The appearance and size is different and the measurement parameters are basically the same; the test notch of 86160 is 0.8mm, which is only suitable for testing materials with a thickness of less than 0.8mm;
The test notch of 86162 is 8mm, which can test films and stick-film glass. It can also directly measure the data of automobile side windshield.